R134a Refrigerant Pressure Temperature Sample Chart

Refrigerant Reference Guide
Name Type
Ozone
Depleting
Oil Type
Charging
System
Refrigerant Major Applications and Notes
R404A HFC No P.O.E Liquid only
For new medium & low temperature applications.
(Can replace R502 but requires careful retro-t
procedure)
R507 HFC No P.O.E
Liquid or
Vapour
For new medium & low temperature applications.
(Can replace R502 but requires careful retro-t
procedure)
Note: The only difference between R404A & R507 is R404A has 4% of R134A added (for patent reasons)
R408A HCFC Yes
Mineral/P.O.E
Alkylbenzene
Liquid only
Interim replacement for R502. (Availability - large
scale reductions from 2005)
R502 CFC Yes
Mineral or
Alkylbenzene
Liquid or
Vapour
No longer manufactured. (High ozone depleting fac-
tor) Used on freezers & med ium temp applications
- see R408A, R404A, R507.
R22 HCFC Yes
Mineral or
Alkylbenzene
Liquid or
Vapour
For air conditioning, medium & occasionally low
temperature applications. (Availability - large scale
reductions from 2005)
R407C HFC No P.O.E Liquid only
For new larger to medium air conditioning & some
smaller applications. (Can replace R22, careful
retro-t prodecure required)
R410A HFC No P.O.E Liquid only
For new smaller (residential type) air conditioning
applications. (Requires high pressure components
& service tools)
R134A HFC No P.O.E
Liquid or
Vapour
For new medium temp & domestic freezers, small
commercial jobs. (Can replace R12 & R500 - but
requires careful retro-t procedure)
SP34E HFC No
Mineral/P.O.E
Alkylbenzene
Liquid only
Interim replacement for R12. (Can be used on
ooded systems ie: temprite systems)
R409A HCFC Yes
Mineral/P.O.E
Alkylbenzene
Liquid only
Interim replacement for R12. (Not recommended for
ooded systems ie: temprite systems)
R12 CFC Yes
Mineral or
Alkylbenzene
Liquid or
Vapour
No longer manufactured. (High ozone depleting fac-
tor) Used on freezers & medium temp applications
- see R409A & SP34E.
R123 HCFC Yes
Mineral or
Alkylbenzene
Liquid only
Interim replacement for R11 - requires careful retro-
t procedure. (Availability - large scale reductions
from 2005)
R11 CFC Yes
Mineral or
Alkylbenzene
Liquid only
No longer manufactured. (High ozone depleting
factor) Used on centrifugal chiller applications - see
R123.
Conversion Tables
Pressure Heat Flow
psig × 6.8948 = kPa
BTU/hr × 0.2931 = watts
psig × 0.069 = bar
watts × 3.412 = BTU/hr
bar × 14.5 = psi
Ton Refrig. × 1200 = BTU/hr
bar × 100 = kPa Ton Refrig. × 3516.8 = watts
kPa × 0.01 = bar kcal/h × 1.163 = watts
Length Temperature
metres × 3.281 = feet °C = 5/9 (°F - 32)
metres × 39.37 = inches
°F = (9/5 × °C) + 32
Pressure Temperature
Conversion Charts
Page 1/3
Free Download