Detailed Construction Scope of Work Template

Attachment #3 QQ-01765
Detailed Scope of Work
Page 10 of 13
4. Cold formed steel shall have a metallic coating complying with ASTM A 1003 and Minimum of
G60 in accordance with ASTM A653.
5. The cold formed steel framed wall shall be anchored to slab or foundation.
6. The cold formed steel members shall be connected per engineered drawings.
7. All cold formed sections shall be manufactured by precision
8. All members shall be straight and free of any defects.
9. Do not proceed with manufacturing prior to review of shop drawings
10. Submit samples 6” long x full panel width showing the metal gauge and panel profile.
11. The panel manufacturer shall have a minimum 10 years of experience in manufacturing roofing.
12. The installer shall have a minimum of 5 years experience in installation of metal roofing in
similar size and scope.
13. The panels and flashing shall be protected and properly packaged to prevent any damage
during the transportation.
14. Store panels and flashing in a dry and safe environment.
15. All dimensions shall be verified prior to fabrication.
16. All panels shall be 24 gauge structural steel.
17. The panels shall be smooth, the final finish shall be per owner’s requirement.
18. Any request for alternate system shall be submitted to project manager in writing at least 10
days prior to ordering the materials.
19. All screws shall be plated steel or stainless steel. They shall have a combination EPDM gasket
and painted flange to match the color of the roofing.
20. The flashing shall be shop fabricated from a material that is a same thickness and finish as the
corrugated panels.
21. Dispose of debris from jobsite.
22. All extra materials shall be transferred to the owner if the owner request it.
Painting:
1. All uncoated structural steel shall be cleaned of all foreign matter and loose scale in accordance
with SSPC-2 and given a one mil coat of red oxide primer. The primer shall meet or exceed the
performance requirements of Federal Specifications TT-P-636.
2. All roof and wall panels, flashing, trim, and other exposed galvanized steel surfaces shall be
factory color coated with 20 year warranty.
3. Furnish primer for touch-up or field painting.
4. The base metal shall be pre-treated and then primed with epoxy type primer for adhesion and
corrosion.
5. All structural framings which are not galvanized, their Surfaces shall be clean and dry free of
dirt, grease, oil, wax, mildew, loose paint, rust and mill scale. The rusty metal surfaces should
be sandblasted or treated, before priming with one shop coat of zinc chromate iron oxide primer,
meeting the Federal Specification TT-P-636.
Windows:
1. Frames and doors shall be installed in accordance with plans and shop drawings in a rigid,
substantial manner and shall be weather tight, waterproof, square, plumb and level.
2. All windows double hung, polished aluminum finish, 3’-0x5’-0”, color to match the trim and as
approved by the owner. The glazing to be double insulated sealed glass. All windows shall be
furnished complete with hardware, and full screen. Windows shall be self flashing to wall panels.
Window locations are as shown on the conceptual plans.
Personnel Doors:
1. Frames and doors shall be installed in accordance with plans and shop drawings in a rigid,
substantial manner and shall be waterproof, weather tight, square, plumb and level.
Page 10/13
Edit Online
Free Download

Detailed Construction Scope of Work Template PDF

Favor this template? Just fancy it by voting!
  •  
  •  
  •  
  •  
  •  
(1 Votes)
5.0
Related Forms
  •  
  •  
  •  
  •  
  •  
2 Page(s) | 3591 Views | 117 Downloads
  •  
  •  
  •  
  •  
  •  
1 Page(s) | 2356 Views | 159 Downloads
  •  
  •  
  •  
  •  
  •  
4 Page(s) | 4891 Views | 104 Downloads
  •  
  •  
  •  
  •  
  •  
1 Page(s) | 14153 Views | 2664 Downloads
  •  
  •  
  •  
  •  
  •  
2 Page(s) | 4157 Views | 296 Downloads